Corrosion Protection & Coatings

Corrosion protection should be selected for the environment in which a helical pile will operate. Buried soil, exposed steelwork, coastal locations and permanent immersion can require different approaches.

SSP's normal protective finish for helical piles is hot-dip galvanizing after fabrication. We review the coating requirements with the customer before production so that the specified finish, inspection criteria and project exposure conditions are understood.

Hot-Dip Galvanizing After Fabrication

The fabricated component is prepared and immersed in molten zinc to form a protective coating on the steel. Zinc provides a barrier and sacrificial protection to the underlying steel.

Galvanizing requirements should cover the complete supplied assembly, including shafts, helices, welds and connection components. For hollow sections, venting and drainage must be considered in the fabrication details. Where internal galvanizing is required, the component design and agreed inspection scope must address it explicitly.

Fastener finish, thread fit and connection assembly also need to be checked. A galvanized pile and an unspecified fastener finish should not be assumed to form a complete corrosion-protection specification.

Our Normal Coating-Thickness Target

SSP's normal production target is an average zinc-coating thickness of at least 85 μm. The final acceptance requirements are confirmed against the order, component type, steel thickness and specified galvanizing standard.

Average thickness and minimum local thickness are different measurements. An average target of 85 μm does not mean that every measurement must be at least 85 μm, unless the contract separately requires that minimum.

For certain non-centrifuged steel articles over 6 mm thick, EN ISO 1461 specifies a minimum local thickness of 70 μm and a minimum mean thickness of 85 μm. These values must not be applied indiscriminately to every component category or steel thickness.

Requests for a higher target, such as an average of 100 μm, are reviewed for the particular product and order. Higher coating thickness should be agreed before manufacture, including its effect on connections and the inspection method.

Confirm the Applicable Coating Standard

A project may specify GB/T 13912, ISO or EN ISO 1461, AS/NZS 4680, ASTM A123/A123M, or an appropriate specification for hardware and fasteners.

These references have different scopes and acceptance provisions. The relevant standard and edition, component category, sampling requirements, local and average thickness criteria, and repair provisions must be agreed for the order. A thickness value alone does not demonstrate compliance with every standard.

Soil and Water Conditions Affect Durability

The corrosion environment depends on factors such as moisture, pH, chlorides, soil resistivity and groundwater. Conditions can vary within the same site.

For marine projects, distinguish atmospheric exposure, splash and tidal zones, and continuous immersion. An atmospheric service-life estimate should not be used as an underwater performance guarantee.

The project engineer should assess the required service life and corrosion allowance using relevant site information. A specified zinc thickness, by itself, is not a guaranteed number of years in service.

Additional Protection Requires Project Review

If hot-dip galvanizing alone does not meet the project's durability requirements, the protection strategy may need additional engineering review. A specified paint system over galvanizing, a corrosion allowance or another protection method may be considered as part of that review.

Additional coatings are not automatic features of SSP's standard supply. Their availability, surface preparation, coating compatibility, application conditions and inspection requirements must be confirmed before quotation and production.

Inspection, Handling and Repairs

The agreed inspection plan should address coating coverage, appearance, thickness measurements, connection fit and repair areas. Coating records should identify the relevant production batch and inspection basis.

Protect the finish during handling, transport and installation. Inspect exposed damage and repair it using the approved method and applicable acceptance criteria. Field cutting or welding may require local coating repair and a separate review of the connection detail.

Discuss Your Corrosion-Protection Requirements

Please send the project location, exposure conditions, soil or water information, design-life requirement, pile drawings and nominated coating standard. Include any required minimum local thickness, average thickness, additional coating system or inspection documentation.

SSP can review the manufacturing and finishing requirements and clarify what is included in the supply before the order is confirmed.

Discuss Your Coating Specification